Which position is best position for endotracheal intubation?

Which position is best position for endotracheal intubation?

The sniffing position
Background: The sniffing position, a combination of flexion of the neck and extension of the head, is considered to be suitable for the performance of endotracheal intubation. To place a patient in this position, anesthesiologists usually put a pillow under a patient’s occiput.

Where does the intubation tube go?

Endotracheal intubation is a medical procedure in which a tube is placed into the windpipe (trachea) through the mouth or nose. In most emergency situations, it is placed through the mouth.

How do you use a fiber laryngoscope?

The Flexible Fiberoptic Laryngoscopy Procedure The flexible laryngoscope is inserted into the patient’s nose, moved into the throat and positioned near the affected area. During the procedure, the patient may feel a strange sensation of the scope through the nose, however he or she will be able to breathe normally.

What is the pharyngeal axis?

Mouth axis (MA) is defined as a straight line drawn parallel to the hard palate; pharyngeal axis (PA) is defined as a line passing through the anterior edge of the atlas and of the second cervical vertebra; laryngeal axis (LA) is defined as a straight line passing through the centres of the inferior (cricoid cartilage) …

How do I check my ETT placement?

A chest radiograph can be used to confirm correct tube position within the trachea, which should be just below the level of the vocal cords and well above the carina. Various techniques have been described to achieve tube positioning above the carina prior to X‐ray confirmation.

What is a fiberoptic scope?

A fiberscope is a flexible instrument that is constructed of a coherent fiber optic image guide that is used to inspect remote areas. A fiberscope is inserted into the item without destroying or disassembling the item of interest.

How do you clean a fiber optic laryngoscope?

Remove device from enzymatic cleaner solution and rinse with lukewarm running tap water for a minimum of one (1) minute to remove all residues and visible soils. 4. Immerse the device in enzymatic detergent. Remove bottom cap and brush items thoroughly using a soft bristle brush, ensuring all visible soils are removed.

Where are the vocal cords located?

larynx
The vocal cords (also called vocal folds) are two bands of smooth muscle tissue found in the larynx (voice box). The vocal cords vibrate and air passes through the cords from the lungs to produce the sound of your voice.

How far above carina should ETT be?

[5,6] It is suggested that the tip of ET should be at least 4 cm from the carina, or the proximal part of the cuff should be 1.5 to 2.5 cm from the vocal cords.

How far do you insert an ET tube?

Introduction. An optimal ETT placement should ensure sufficient distance (2–5 cm) between the tip of the ETT and the carina3 and sufficient distance (1.5–2.5 cm) between the proximal margin of the cuff to the vocal cords.