What is CT fault?

What is CT fault?

Current transformers used to sense ground fault (zero sequence) currents, such as in a three-phase installation, may have three primary conductors passed through the ring. Only the net unbalanced current produces a secondary current – this can be used to detect a fault from an energized conductor to ground.

Do current transformers fail?

Three current transformers have failed, exploiting near the circuit breakers in the same phase, the analysis and the root cause of this fault has been developed in a special condition, the coast of Peru, and the novel contribution is a recommendation for the physical layout in substations, insulation coordination and …

What causes CT failure?

1) shows that the leading reasons for early failure are dominated by five main classifications: corrosion, mechanical damage, manufacturing flaws (or defects), operator error, and hydrogen sulfide (H2S) cracking. These groups account for approximately 94% of all failures.

Which relay is used for internal fault detection in power transformer?

Differential relays
Differential relays are widely used in the protection of power transformers. However, these relays are susceptible to mistaking the inrush currents, which are generated during the turning on of transformers.

What is burden of CT?

The burden of the CT is the resistive load used to create the voltage on the output. It varies with turns ratio, desired output and current rating of the primary.

What is CT knee point?

The point where CT saturates also known as the knee point, which according to IEC, knee point is the voltage at which a 10% increase in voltage of CT secondary results in a 50% increase in secondary current.

Why do current transformers fail?

One of the causes of CT failures is high values of insulation power factor. Research indicates that with increasing primary insulation power factor values, partial discharges develop between the paper insulation leading to its exponential decay with the end result of an ultimate CT failure.

What is the most common CT system failure?

CT System Sliprings and Brushes “The most common failure on a CT system is obviously the tube,” says Sam. “But, the carbon brushes for the slipring will also cause problems if they’re not replaced when they should be.”

What is Buchholz alarm?

It is a kind of oil and gas activated security relay. The Buchholz relay purpose is to give the protection to a transformer from the different faults happening in the transformer like the Short circuit, inter-turn, core, incipient, etc. This relay will sense these faults and shuts the alarm circuit.

What is P1 and P2 in current transformer?

P1 indicates the side on which the current source is located, whilst P2 indicates the load side.

Why is CT secondary closed?

When CT of secondary is open, the VA is totally consumed in core heating as a core loss. As per the law of energy conservation, the energy balancing is always there, the VA consumed by CT is equal to the core loss of the CT when secondary is open-circuited. For this reason, CT should be never kept open-circuited.

What is RCT in current transformer?

The RCT indoor current transformer is used for metering and relaying applications in medium voltage (5 – 15 kV) switchgear. The RCT indoor current transformer is used for relay- ing and metering applications in medium voltage (5 – 15 kV) switchgear. The RCT-5 is sized for 5 kV switchgear.

What happens if CT secondary is open?

What happens when the secondary of CT is Open- Circuited? It is very clear that the net flux in the core is equal to flux due to primary current minus flux due to secondary current. If CT is kept open-circuited, no current will flow in the secondary, and consequently, no secondary flux will be set up in the core.